is designed for casing string cementing quality control (casing size 55-155 mm).

 

Description

Features and Advantages

• the tool is operated through a one-core cable of up to 6000 m length, with computerized logging stations equipped with fast-acting analog-digital converters which allow to record the full wave picture (of GEKTOR type);
• tool conveyance to the investigation interval through the drill pipe (inner diameter 50 mm).

Specifications

Sonde formula

I20.25I11.5P

Centralizers

lever-type

Transmitter

magnetostrictive, radial

Receiver

piezoceramic

Transmitter inherent frequency, kHz

20

Max. operating temperature, oC

120

Max. hydrostatic pressure, MPa

60

Borehole tool dimensions, mm:

   diameter (without centralizers)

    length

 

36

2400

Used cables core number, pcs

1

Weight, kg

up to 10

Certificate