is designed for quick oil saturation estimating and rock ultimate composition due to multichannel registration of inelastic scattering/radiative capture energy spectra but also due to recording an additional time spectrum of induced GR integral flux within fast neutron pulses interval.
For quantity reduction of round-trip operations and simultaneous
recording of several parameters, TzSP-С/О-90 tool can be produced as an integrated tool with the TzSP-GK-S-90 digital downhole gamma-ray spectrometry tool (100 mm diameter in complex) and also be completed with a thermometry channel.
Downhole tool is to be run with the log recorder Hector, Vulcan V3 and with tree-core cable.
Features and Advantages
• simultaneously-consecutive registration of 3 energy spectrums according to 512 quantization signal levels according to amplitude and summary gamma-radiation temporal spectrum according to 50 channels;
• the use of high-frequency impulsive (10 khz) fast neutron ING-06 radiator of increased power (more 108 n/sec) and operation resource more 200 hours;
• technological program package for measurements process control and application program package for primary C/O logging data processing.
Application field
Estimation of oil-and-gas saturation coefficient on value of the relative amplitude of C/O and Ca/Si anomalies taking into account layers lithology, neutron and effective porosity of the investigated collectors.
Measurement of inelastic scattering gamma-ray, radiation capture gamma-ray and epithermal neutron spacetime and energy distributions provides the principle conditions for calculating of partial contributions from the basic oil-, water- and rock-forming element nuclei (C, O, H, Si, Ca, Fe, Cl, etc.) as well as for calculating different relations associated by the correlation dependences with the filtration-capacity parameters, rock lithology and fluids (oil, water) which saturates them.
Terrigenous reservoir oil saturation KH measurements range, % |
1-100 |
Basic relative error limits of KH measurements under normal conditions, % |
±7 |
Scintillation detector BGO (bismuth germanate) size, mm |
50×150 |
Cs-137 line resolution, % |
up to 12 |
Neutron generation frequency, kHz |
10 |
Tool power supply, V |
200 |
Time analyzer bandwidth, microsec |
2.0 |
Width of the window time analyzer, ms |
2 |
Number of registratable energy spectrum and channels in the spectrum |
3×512 |
Number of registratable time spectrum and channels in the spectrum |
1×50 |
“Dead” time of measuring channel, ms |
up to 3 |
Tool retrieving speed, m/h |
50-70 |
Max. operational temperature, °C |
120 |
Max. hydrostatic pressure, MPa |
60 |
Tool dimensions, mm: diameter length |
100 3200 |
Weight, kg |
50 |
The TzSP-C/O-90 tool is certified.